INNOVATIVE ENGINEERING SOLUTIONS for YOUR PUMP and GEAR BOX NEEDS
Emotron FDU - AC Drives

Technical Specs
-
Rated Power: 0.75 – 3,000 kW
-
Supply Voltage: 230 – 690 V, 3-phase
-
Rated Current: 2.5 – 3,000 A
-
Protection Class: IP54
-
Approvals: CE, UL, DNV, GOST R
-
Rated power11-132 kW
-
Supply voltage230-480 V, 3-phase
-
Rated current25-244 A
-
Protection classIP20 (optional 21)
Features
-
A number of options let you customize the Emotron FDU 2.0 functionality and fully utilize the product according to your needs. Four different options can be combined..
-
Up to three I/O boards can be connected. This opens for multiple control of up to seven pumps or compressors without PLCs or other equipment.
-
Communication options include fieldbus communication via Profibus and DeviceNet, Industrial Ethernet communication via Modbus/TCP, EtherCAT and Profinet, and serial communication via RS232 or RS485 with Modbus RTU
-
PTC and PT100 sensors can be connected to control motor temperature and give process feedback without using a transmitter.
-
This option board offers protection from unexpected start during mechanical maintenance, in accordance to the EN-IEC 62061:2005. SIL3 & EH- ISO 13849-1:2006 Category 3 standard.
-
EMC filter according to class C3 - 2nd Environment included as standard in all drive units.
-
A 12-pulse rectifier offers a cost-efficient reduction of harmonic current distortions. It reduces power losses in equipment such as transformers and conductors, and eliminates the need to over-dimension these components.
-
Makes it possible to supply the control circuits via an external 24 V AC/DC supply to maintain communication and set up the system when 3-phase mains is not connected. Provides communication backup if 3-phase main power supply fails.
Emotron VFX - AC Drives

Technical Specs
EMOTRON VFX IP54 Version
-
Rated Power: 0.75 – 3,000 kW
-
Supply Voltage: 230 – 690 V, 3-phase
-
Rated Current: 2.5 – 3,000 A
-
Protection Class: IP54
-
Approvals: CE, UL, DNV, GOST R
-
-
EMOTRON VFX IP20/21 Version
-
Rated Power: 11 – 132 kW
-
Supply Voltage: 230 – 480 V, 3-phase
-
Rated Current: 25 – 244 A
-
Protection Class: IP20 (optional IP21)
Features
-
A crane I/O expansion board offers efficient riding, lifting, and speed control, and a safety system that activates the mechanical brakes should dangerous loads be detected.
-
For extremely short braking time a brake chopper is available as a factory-installed option. It is used in combination with brake resistors dimensioned according to the specific application demand.
-
Communication options include fieldbus communication via Profibus and DeviceNet, Industrial Ethernet communication via Modbus/TCP, EtherCAT and Profinet, and serial communication via RS232 or RS485 with Modbus RTU.
-
PTC and PT100 sensors can be connected to control motor temperature and give process feedback without using a transmitter.
-
An encoder can be connected for more accurate speed control or for increased safety through deviation control in crane applications.
-
This option board offers protection from unexpected start during mechanical maintenance, in accordance to the EN-IEC 62061:2005. SIL3 & EH- ISO 13849-1:2006 Category 3 standard. No contactor is required.
-
EMC filter according to class C3 - 2nd environment included as standard in all drive units.
-
A 12-pulse rectifier offers a cost-efficient reduction of harmonic current distortions. It reduces power losses in equipment such as transformers and conductors, and eliminates the need to over-dimension these components.
-
Makes it possible to supply the control circuits via an external 24 V AC/DC supply to maintain communication and set up the system when 3-phase mains is not connected. Provides communication backup if 3-phase main power supply fails.
Emotron AFE - Active Front End Drives

Technical Specs
-
Rated Power: 55 – 1,000 kW
-
Supply Voltage: 380 – 690 V, 3-phase
-
Rated Current: 109 – 1,800 A
-
Protection Class: IP54
Emotron CDU / CDX - Motor-Mounted AC Drives

Technical Specs
-
Motor Construction: B3, B5, B35, V1, V18, etc.
-
Rated Power: 3 – 22 kW
-
Supply Voltage: 380 – 480 VAC / 480 – 525 VAC
-
Protection Class: IP55
-
Approvals: Global standards
-
Ambient Temperature: 0 – 40 °C during continuous operation
-
Vibration and Shock: IEC-EN60721-3-3 class 3M7
-
Altitude: 0 – 1,000 m above sea level
-
Atmospheric Pressure: 86 – 106 kPa
-
Relative Humidity: 0 – 90%, no condensing
Emotron DSV / GSV - Lift Drives

Technical Specs
Emotron DSV / Emotron DSV Plus
-
Output Power: 6.6 – 165 kVA
-
Motor Power: 3 – 132 kW
-
Supply Voltage: 3 × 400 V ±10%
-
Frequency: 50 – 60 Hz ±5%
-
Pulse Current: 20 – 375 A
Emotron DSV Flat / Emotron GSV DC Drive
-
Output Power: 15 – 35 kVA
-
Motor Power: 7.5 – 27 kW
-
Supply Voltage: 3 × 400 V ±10%
-
Frequency: 50 – 60 Hz ±5%
-
Pulse Current: 40 – 86 A
Features
-
Emergency evacuation is available as an option, using a battery or a UPS system. A lift, which has stopped between floors due to power failure, is automatically and safely moved upwards or downwards to the nearest landing to let passengers exit
-
Regenerative braking with line-recovery unit is available on request, as is safe stop according to EN 954-1. Excellent CE and EMC performance is achieved with the Emotron AddOn-filter.
-
Among the options are also motor and mains filters. An encoder can be connected for more accurate speed control. Option boards can be ordered for fieldbus and transmitting systems. Other options are net recovery and current regeneration.
Emotron FlowDrive

Technical Specs
-
Rated Power: 0.75 – 160 kW @ 400 VAC
-
Supply Voltage: 230 – 690 VAC, 3-phase
-
Rated Current: 2.5 – 295 A
-
Protection Class: IP54 / IP20 / IP21
-
Approvals (Emotron): CE, EAC
Features
-
Serial communication via RS232 or RS485 with Modbus RTU
-
Industrial Ethernet communication (Modbus/TCP, Profinet, Ethernet-IP and EtherCAT)
-
Fieldbus communication (Profibus DP, DeviceNet)
-
Extended digital I/O boards
-
PTC/PT100 Motor protection board (PTC + max 3 PT100)
-
External control panel
-
Extended EMC protection (1st environment Category C2)
-
Safe stop without a contactor, i.e. Safe Torque Off (STO), for meeting the requirements of machine safety
-
Standards EN 13849-1 and EN 62061
-
Motor filters (output choke, sinus filter, common mode filter)
-
Active front end, AFE, for low harmonics