top of page

 

TeSys LRD01 thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors less than 0.06kW@400V thanks to a thermal range 0.10-0.16A, a tripping class 10A and phase unbalance protection. LRD01 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 0.10-0.16A, a tripping class 10A and phase unbalance detection, it protects motors less than 0.06kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential).

 

Main
range

TeSys

 
product name

TeSys LRD

 
product or component type

Differential thermal overload relay

 
device short name

LRD

 
relay application

Motor protection

 
product compatibility

LC1D25
LC1D09
LC1D12
LC1D18
LC1D38
LC1D32

 
network type

DC
AC

 
thermal overload class

Class 10A conforming to IEC 60947-4-1

 
thermal protection adjustment range

0.1…0.16 A

 
[Ui] rated insulation voltage

Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1

 
Complementary
network frequency

0...400 Hz

 
mounting support

Plate, with specific accessories
Rail, with specific accessories
Under contactor

 
tripping threshold

1.14 +/- 0.06 Ir conforming to IEC 60947-4-1

 
auxiliary contact composition

1 NO + 1 NC

 
[Ith] conventional free air thermal current

5 A for signalling circuit

 
permissible current

3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit

 
[Ue] rated operational voltage

690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1

 
associated fuse rating

4 A gG for signalling circuit
4 A BS for signalling circuit

 
[Uimp] rated impulse withstand voltage

6 kV

 
phase failure sensitivity

Tripping current 130 % of Ir on two phase, the last one at 0

 
control type

Red push-button: stop
Blue push-button: reset

 
temperature compensation

-20…60 °C

 
connections - terminals

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end

 
tightening torque

Control circuit: 1.7 N.m - on screw clamp terminals
Power circuit: 1.7 N.m - on screw clamp terminals

 
height

66 mm

 
width

45 mm

 
depth

70 mm

 
net weight

0.124 kg

 
Environment
protective treatment

TH conforming to IEC 60068

 
IP degree of protection

IP20 conforming to IEC 60529

 
ambient air temperature for operation

-20…60 °C without derating conforming to IEC 60947-4-1

 
ambient air temperature for storage

-60…70 °C

 
flame retardance

V1 conforming to UL 94

 
mechanical robustness

Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7

 
dielectric strength

1.89 kV at 50 Hz conforming to IEC 60947-1

 
standards

EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495

 
product certifications

IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS

LRD01 Thermal Overload Relay

SKU: LRD
₹1,160.00Price
Quantity
    bottom of page